8/19/2020 0 Comments Baumuller Drive Fault Codes
We possess 5 Baumuller b maxx BM4400 guides accessible for free PDF download: Coaching Handbook Manual, Compact Guide, Operating Handbook.While these drives rarely fall short, they may need support from period to time.
Baumuller Drive Fault Codes Code Analysis MessageYour system produces a fault code, or error code analysis message, when something isnt functioning correctly.However, complications with your Indramat motion control program may need professional assistance.Either way, get in touch with us instantly whenever you discover an Indramat mistake code. We will walk you through troubIeshooting over the telephone, and we possess charter plane tickets obtainable when you need on-site assistance fast. During a fault problem, the electronic agent will screen requirements to notify the user to these circumstances. The pursuing can be a listing of possible codes along with some possible factors for the code and some options that may quickly clear the program code enabling the push operation to carry on. Cycle power to the commute and verify for reoccurrence of the mistake. The commute should today operate to the defined setpoint by analogue insight. This is definitely from the matching manual for the Micromaster 420 series, but it is usually hidden within the manual which many people most most likely dont actually have. For even more details or to demand a quotation, please call 800-691-8511 or email salesmroelectric.com. ![]() Take note To reset the mistake program code, one of three strategies listed beneath can be utilized: 1. Period the energy to the push. Push the switch on the B0P or AOP. Via Digital Input 3 (default environment). Motor power (P0307) must match to inverter strength (P0206) 2. Motor wire and engine must possess no brief- circuits or earth errors 4. Electric motor must not really be blocked or inundated Enhance the ramp period Reduce the boost level. Source voltage (P0210) must are located within limits pointed out on rating dish 2. DC-link voltage controller must end up being allowed (P1240) and parameterized properly 3. Offer must not be prone to short-term downfalls or voltage reductions. Atmosphere inlet and wall socket points are not obstructed Ambient temperatures could become increased than chosen for the inverter. Check electric motor cable connection and motor for short- circuits and globe flaws 4. Verify whether the electric motor parameters correspond with the electric motor being utilized 5. Reduce the increase 8. Examine whether the engine is obstructed or bombarded. Enhance ramp down periods Take note: Vdc-max control is energetic, ramp-down moments will be automatically enhanced. G0611 (electric motor i2t period constant) should end up being set to suitable value 2. G0614 (Electric motor i2capital t overload caution level) should end up being set to ideal level 3. Index 0: Parameter configurations for result identical Catalog 1: Parameter configurations for input identical Catalog 2: Parameter configurations for input do not match to ADC type. Index 0: Parameter settings for result identical Catalog 1: Parameter settings for insight identical List 2: Parameter configurations for result do not correspond to DAC type. As a outcome, some functions may not work correctly, because there is usually no normal load condition. Check out that G0700 2 (for digital input control) or P0700 1 (for BOP control). Check that the setpoint is usually existing (0 to 10V on Fatal 3) or the setpoint has been entered into the proper parameter, based upon the setpoint source (G1000). Now use a switch between terminals 5 and 8 on the control board.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |